Bearing Capacity - SPT
The "Bearing capacity" frame serves to verify the pile vertical bearing capacity. The program calculates vertical bearing capacity according to the method selected in the Settings frame:
The design value of the load should be input.
The analysis can be performed for the field test with the highest utilization, the average from all tests or a selected test from the combo list.
Further, it is necessary to select verification methodology according to safety factors or limit states. Required safety factor or base and shaft reduction coefficients are input in this frame.
The "In details" button opens the dialog window with detailed results.
"Bearing capacity" frame