Point Flow
The frame "Point flow" contains a table with the list of points with a flow. Adding a point flow is performed in the "New point flow" dialog window.
The input point flows can also be edited on the desktop with the help of active objects.
The following boundary conditions can be specified:
a) Pore pressure at a point
- Numerically - the value of pore pressure at a given point is specified [kPa, ksf]
- By specifying the location of groundwater table (total head) - coordinate of GWT is specified
b) Point inflow/outflow
Pumping/injection rate is specified [m3/day/m, ft3/day/ft]