Verification According to Limit States
The verification according to limit states is selected in the "Pile CPT" tab, including the setting of the pile bearing capacity reduction coefficient. When using the NEN 6743 standard the program automatically performs the verification analysis as specified by this standard and therefore the frame "Settings" is not accessible. Pile verification for the first limit state assumes the formula:
where: | Fs,d | - | design pile load |
γt | - | reduction coefficient of bearing capacity | |
Fr,d | - | design pile bearing capacity |